How do I prevent gage glass failure in high-pressure steam service?
Use the appropriate borosilicate or tempered glass rated for your operating pressure and temperature. The 300L series is designed for demanding service — ensure the isolation valves (gauge cocks) are closed before any glass replacement, and always use proper safety shields. Never use soda-lime glass in steam applications.